The AC Surge Protective Device is for protecting electrical systems from high-energy surges such as lightning. It works in a fast manner, with an array of discharge capacitance. It provides consistent performance to ensure the safety of the equipment it is charged with. Intended for home and business applications, this unit complies with safety standards in various countries to provide you with the finest security each time.
Transient Surge Suppressor -BT BNM 100
BT BNM 100
801021
1. Adopt hermetical GDT technology.
2. Lightning impulse current withstand max. 100kA (10/350us)
3. Extremely low voltage protection level.
4. Double terminals for parallel or series (V-shape) connection.
5. Multifunctional connection for conductor and busbars.
AC T1 Surge Protective Device
SPD Manufacturers -BT BCM 25 RM/2+N
BT BCM 25 RM/2+N
801037
1. 10/350μs, 8/20μs sparkgap, Two-phase TT/TN(“2+1” circuit) lightning surge protector.
2. Lightning impulse current withstand max.25kA (10/350μs) L-N, max.100kA (10/350μs) N-PE.
3. Adopt hermetical GDT technology, high follow current extinguishing capacity.
4. Extremely low voltage protection level.
5. Double thermals for parallel or series (V-shape) connection.
6. Multifunctional connection for conductors and pure copper busbar.
7. Green light indicates power functional mode (L-N module).
2. Lightning impulse current withstand max.25kA (10/350μs) L-N, max.100kA (10/350μs) N-PE.
3. Adopt hermetical GDT technology, high follow current extinguishing capacity.
4. Extremely low voltage protection level.
5. Double thermals for parallel or series (V-shape) connection.
6. Multifunctional connection for conductors and pure copper busbar.
7. Green light indicates power functional mode (L-N module).
AC T1 Surge Protective Device
Surge Arrester Manufacturer -BT BCM 25 RM/1+N
BT BCM 25 RM/1+N
801035
1. 10/350μs, 8/20μs sparkgap, Single-phase TT/TN(“1+1” circuit) lightning surge protector.
2. Lightning impulse current withstand max.25kA (10/350μs) L-N, max.100kA (10/350μs) N-PE.
3. Adopt hermetical GDT technology, high follow current extinguishing capacity.
4. Extremely low voltage protection level.
5. Double thermals for parallel or series (V-shape) connection.
6. Multifunctional connection for conductors and pure copper busbar.
7. Green light indicates power functional mode (L-N module).
2. Lightning impulse current withstand max.25kA (10/350μs) L-N, max.100kA (10/350μs) N-PE.
3. Adopt hermetical GDT technology, high follow current extinguishing capacity.
4. Extremely low voltage protection level.
5. Double thermals for parallel or series (V-shape) connection.
6. Multifunctional connection for conductors and pure copper busbar.
7. Green light indicates power functional mode (L-N module).
AC T1 Surge Protective Device
Storm Surge Protection -BT BCM 25 RM
BT BCM 25 RM
801030
1. Adopt hermetical GDT technology, high follow current extinguish capacity.
2. Lightning impulse current withstand max.25kA (10/350μs).
3. Extremely low voltage protection level.
4. Double terminals for parallel or series (V-shape) connection.
5. Multifunctional connection for conductor and busbars.
6. Green light indicates functional mode.
7. Mode of protection: L-N/L-PE/L-PEN/N-PE.
2. Lightning impulse current withstand max.25kA (10/350μs).
3. Extremely low voltage protection level.
4. Double terminals for parallel or series (V-shape) connection.
5. Multifunctional connection for conductor and busbars.
6. Green light indicates functional mode.
7. Mode of protection: L-N/L-PE/L-PEN/N-PE.
AC T1 Surge Protective Device
Power and Surge Protection -BT BCM 25 RM/2P
BT BCM 25 RM/2P
801032
1. Adopt hermetical GDT technology, high follow current extinguish capacity.
2. For single-phase TN system; Total lightning impulse.current limp withstand max. 100kA (10/350us).
3. Extremely low voltage protection level.
4. Double terminals for parallel or series (V-shape) connection.
5. Multifunctional connection for conductor and busbars.
6. Green light indicates functional mode (L-PE modules).
2. For single-phase TN system; Total lightning impulse.current limp withstand max. 100kA (10/350us).
3. Extremely low voltage protection level.
4. Double terminals for parallel or series (V-shape) connection.
5. Multifunctional connection for conductor and busbars.
6. Green light indicates functional mode (L-PE modules).
AC T1 Surge Protective Device
TVSS Surge Suppressor -BT BCM 25 RM/3P
BT BCM 25 RM/3P
801033
1. Adopt hermetical GDT technology, high follow current extinguish capacity.
2. For three-phase TN-C system; Total lightning impulse.current limp withstand max. 100kA (10/350us).
3. Extremely low voltage protection level.
4. Double terminals for parallel or series (V-shape) connection.
5. Multifunctional connection for conductor and busbars.
6. Green light indicates functional mode (3* L-PEN modules).
2. For three-phase TN-C system; Total lightning impulse.current limp withstand max. 100kA (10/350us).
3. Extremely low voltage protection level.
4. Double terminals for parallel or series (V-shape) connection.
5. Multifunctional connection for conductor and busbars.
6. Green light indicates functional mode (3* L-PEN modules).
AC T1 Surge Protective Device